Coraye / Docs
WebsiteBlogContactDashboard
English
English
  • DOCUMENTATION
  • Dashboard
    • Create an account
    • Activate a license
    • Personal data
    • Support Download
  • INSTALLATION AND MAINTENANCE
  • Getting started with Coraye
  • Installation under Mac OS
  • Installation under Windows
  • Installation of the Windows driver for your spectrophotometer
  • Interface presentation
  • Plugins installation and management
  • Visualization modules
    • Gamut Viewer
    • Spectral viewer
  • Calibration
    • Create a profile from a standard reference
    • Customization of targets
    • Create a profil from a calibration
    • Printing chart RGB
    • How to use a ruler with a Xrite ColorMunki Photo or an Xrite I1 Studio
    • Create an icc profile from an average of measured charts
  • Colors Management
    • Capturing a color
    • Capturing a Light
    • Color finder module
    • Color converter module
    • Delta E Finder
    • Density
  • Colors tables
    • Colors tables
    • Example of using a color table with Photoshop
    • Create swatches containing reproducible colors in print
    • Create a color table from a spot color chart measurement
    • Export a Color Table to Wasatch RIP
    • Export a Color Table to EFI Fiery RIP
    • Export a Color Table to Onyx
    • Export to ColorGATE
    • Export a Color Table to Caldera RIP
    • Export a Color Table to Epson Edge Print RIP
    • Export a color table to the Roland Versaworks RIP
    • Export to Adobe Photoshop
    • Export to Adobe Illustrator
    • Export to Adobe Indesign
    • Import / Export a color table with the spectro densitometer XRite eXact
    • Convert color tables to make them printable
    • Reproduction report of colors contained in a table
    • Rename the colors of a table
    • Create a color chart
    • Prepare to print and cut a color chart
    • Prepare a color chart for metallic printing
  • QUALITY CONTROL
    • Print Control
    • Create a reference for Proof
    • Create a reference from a printed Mediawedge
    • Create a reference from a printed chart
    • Create a reference from the values of an imported range
    • Create a reference from a spot color swatch
    • Control a grayscale
  • First steps: Control of a standardized Mediawedge
  • Chart control
  • Compare and edit chart measures
  • Installation Problems
    • Plugin fail to install
  • Plugins
    • Barbieri
      • Barbieri LFP et LFP qb
      • Barbieri LFP qb Sensing Unit
      • Barbieri Spectropad
      • Gateway Barbieri
    • Konica Minolta CM-26
Powered by GitBook
On this page
  • USB connection or Wi-Fi network
  • USB connection
  • WIFI network connection
  • Sample measurement with the "Color Capture" function

Was this helpful?

  1. Plugins
  2. Barbieri

Barbieri LFP qb Sensing Unit

PreviousBarbieri LFP et LFP qbNextBarbieri Spectropad

Last updated 3 years ago

Was this helpful?

Spot measurement The spectral unit can be detached from the platform to use it as a manual device for spot measurements. Switch off platform and detach the spectral unit by releasing the button on the back side of the spectral unit.

Switch on spectral unit by pressing the button on back side. The display will show the following content: The "Calibrate device" button performs an automatic calibration of the device by automatically inserting the internal reference white and performing calibration.

USB connection or Wi-Fi network

Coraye gives you the possibility to connect your Barbieri LFP spectrophotometer via the USB port or via the Wi-Fi network connection. First of all, make sure that the Barbieri plugin is installed and that the Sensing Unit is turned on.

USB connection

‌When your Barbieri LFP qb Sensing Unit is connected via usb, it will be detected and displayed at the top right in the Coraye window. You won't have to do anything else.

WIFI network connection

If you choose to connect your Barbieri LFP qb Sensing Unit to a network via a WIFI connection, you must enter its IP address.

First step: Retrieve the IP address of the Sensing Unit: Press the "Settings" cogwheel to access the WI-FI icon.

Click on the "Wi-Fi" icon ‌

The IP address appears on the screen

The Wi-Fi parameters are configurable by clicking on the "device to WLAN" button ‌

Second step: transfer the IP address in Coraye‌

Click on the "Enable network instrument detection" button located at the top right of the Coraye window‌

In the window that appears, type the IP address of the Barbieri LFP Sensing Unit (Ex: 192.168.1.27) then select the model of the spectrophotometer (In our example: Spectro LFP qb unit). Click on the "Validate" button‌

Congratulations your Barbieri Sensing Unit is ready to use‌

Sample measurement with the "Color Capture" function

To measure color samples, press the "Measure" button on the touchscreen of the Sensing Unit.

The colors will appear in the Coraye window

The use of the "Color capture" module is detailed in the "Color capture" tutorial:

Capturing a color
Capturing a color